Shanghai Zhoubo welding & cutting technology CO.,LTD.

Integrity, Professional, Stability, Innovation

Manufacturer from China
Verified Supplier
10 Years
Home / Products / Kjellberg HiFocus Machine Consumables /

Kjellberg Plasma Cutter Parts .11.848.421.145C G121C For Kjellberg Hifocus Plasma Machine

Contact Now
Shanghai Zhoubo welding & cutting technology CO.,LTD.
Visit Website
Country/Region:china
Contact Now

Kjellberg Plasma Cutter Parts .11.848.421.145C G121C For Kjellberg Hifocus Plasma Machine

Ask Latest Price
Video Channel
Brand Name :Plasma Consumables
Model Number :.11.848.421.145C G121C
Certification :ROHS/ SGS
Place of Origin :China
MOQ :5pcs
Price :negotiation
Payment Terms :T/T or western Union
Supply Ability :10,000pcs per month
Delivery Time :Prompt goods
Packaging Details :Manufacturer packing
Product Name :Plasma Consumables
Application :Plasma Cutting Machine
Standard :Manufacturer production standard
type :.11.848.421.145C G121C
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

Kjellberg Plasma Gas Guide .11.848.421.145C G121C For Kjellberg Hifocus Plasma Machine

Shanghai ZhouBo Welding & Cutting Technology company are a professional manufacturer of plasma cutter consumables, Our company is located in the Shanghai City, China ,it was established in 2007,but we had 10 years manufacturing experience in this field, the new factory covers an area of more than 10000 square meters .There are 50-100 workers and 20 research engineers.
We are a professional manufacturer of plasma cutter consumables.
Customer Satisfaction
If you worry about our products’ quality, I can give you some samples to test by free. Please don't hesitate to contact us if you have any questions or concerns before or after your purchase. We are committed to your 100% satisfaction.
Shipping and handing
1. DHL is our preferred shipping method. Meanwhile TNT, EMS, Fedex, UPS are available.
2. Make sure to leave telephone number when filling your buyer information.
3.You can check the goods where it is in transit through tracking NO .
Refund(Echange Only)
1.If you are not satisfied with your purchase, you can echange the items received. you must contact us within 5 days of the receipt
of your order. And you should pay all additional shipping fees incurred and the items returned should be kept in their original
status.
2.If you wish to echange defective or incorrect shipped goods, please contact us within 5 days after receiving the goods.
Notes
1. The buyer are responsible for any insurance you think necessary.
2. The processing time for a specific order varies with the product type and stock status. Mostly, processing time can be 3 to 15 working days.

MachineHEC NO.Thum NO.Ref NO.Description


























FineFocus 800
FineFocus 900

K631730V433011.833.101.1550Swirl Gas Cap 3.0
K631735V433511.833.101.155Swirl Gas Cap 3.5
K631740V434011.833.101.156Swirl Gas Cap 4.0
K631745V434511.833.101.157Swirl Gas Cap 4.5
K631750V435011.833.101.158Swirl Gas Cap 5.0
K631760V436011.833.101.159Swirl Gas Cap 6.0
K631860V456011.833.111.159Swirl Gas Cap 6.0
K42192T50211.841.721.081Protective Cap Percut 370.2
K42202T52211.836.921.271Swirl Gas Nozzle PerCut 370.2®
K42201T52111.836.901.271Swirl Gas Nozzle PB-S77®/PB-S80®
K521230T303011.836.901.163Nozzle Cap (12x1,5 30°cw)
K521245T304511.836.901.164Nozzle Cap (12x1,5 45°cw)
K521345T314511.836.901.1641Nozzle Cap (12x1,5 45°ccw)
K521260T306011.836.901.165Nozzle Cap (12x1,5 60°cw)
K521360T316011.836.901.1651Nozzle Cap (12x1,5 60°ccw)
K12715T2115Y11.846.921.415Nozzle O2 120A
K12720T2120Y11.846.921.420Nozzle O2 200A
K12725T2125Y11.846.921.425Nozzle O2 250A
K12727T2127Y11.846.921.427Nozzle O2 300A
K12730T2130Y11.846.921.430Nozzle O2 360A
k11025T2525.11.836.911.625Nozzle T2525 ArH2 280A 2.5mm
k11027T2527.11.836.911.627.Nozzle T2527 ArH2 360A 2.7mm
k1927T2427.11.846.911.627Nozzle T2427 ArH2 360A 2,7mm
k1929T2429.11.846.911.629Nozzle T2429 ArH2 440A 2,9mm
K7244T10411.836.921.1542Swirl Ring (3x0,4 cw)
K7241T10111.836.921.153Swirl Ring (6x0,8 cw)
K7251T11111.836.921.1531Swirl Ring (6x0,8 ccw)
K7242T10211.836.921.154Swirl Ring (3x0,8cw)
K7252T11211.836.921.1541Swirl Ring (3x0,6 ccw)
K0212T012Y11.844.921.300-AGSilver Electrode
K0102S002Y11.843.021.320-AGCathode, Ag
K0112S012X11.843.121.310-AGCathode, Ag
K0122S04211.842.411.510Cathode, HiFinox® (i)
K0132S05211.842.511.510Cathode, FineFocus® (i)
K0221T051.11.836.911.500 
K92211T90111.844.901.152Cooling Tube
K93221V95111.828.911.230Cooling Tube



Technical Support:
How to maintain CNC cutting machine

CNC cutting machine working site and working environment is relatively poor, relatively large metal dust. Therefore, the machine must be fully cleaned and maintenance, the person responsible for the equipment lubrication, maintenance and maintenance work!


A. Safe operation:

1. CNC cutting machine is a sophisticated equipment, so the cutting machine operation must do sanding (man, machine, posts)

2 the operator must go through professional training and be able to skillfully operate, non professionals do not move.

3. In the operation must be confirmed without external interference, everything is normal, the cutting plate dipping in the cutting platform, the plate can not be more than cutting range (Note: in hoisting to be careful).

B. Daily maintenance and maintenance:

1. Each work, must clean up the dirt and guide rail machine, make the bed is kept clean, air and power is shut down work. At the same time emptying machine tube with residual gas.

2 if you leave the machine for a long time to turn off the power, in case of non professional operation.

3 observe the machine horizontal, vertical guide rail and rack surface with no lubricating oil, to keep the good lubrication!

C. Weekly maintenance and maintenance:

1 weekly to the machine for a comprehensive clean-up, horizontal, vertical guide rail, transmission gear rack cleaning, filling the lubricating oil.

2 check the horizontal and vertical rail cleaning device is working properly, if not properly and timely replacement.

3 check all the torch is loose, clean up the garbage of the ignition gun ignition, maintain normal.

4 if there is automatic adjustment of the device, the detection is sensitive, whether to replace the probe.















































































Inquiry Cart 0